DoorTek Blog
Mar 09
Feb 20
DoorTek has designed a ManTrap Interlock Hardware system that preserves anti-pass-back. The system places a very nice Interlock Request plate on either side of the ManTrap. The request plate has a Interlock Request Button, a red led that indicates the locked-out status, and a green led that indicates Interlock Request Granted. A cardholder, upon approaching the door, can tell if the door is blocked by the red led. If the door is not blocked, the cardholder presses the Interlock Request button. Upon acceptance of the request the green led will be lit. The cardholder then presents the card to the reader. When the green led is lit the reader is active and the opposite side is totally blocked. Only once the door is closed and locked will the other side become available for activation.
Dan
Feb 19
Dan
Feb 13
Can DoorTek supply add-on card orders for the old Xetron XE-1 wiegand swip card type? Yes we can. They are still being made but are going up in price. They will likely be phased out at some point, but are still available now. Wiegand style readers can be replaced with proximity readers with identical output type. What does this mean? It means you can up grade the human interface, the readers and cards, without replacing your electronics. Call us for more information.
1